Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
5
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Characteristics HE**D
Technical data NG06 NG10
General
Design Directional spool valve
Actuation Solenoid
Nominal size DIN NG06 / CETOP 03 / NFPA D03 DIN NG10 / CETOP 05 / NFPA D05
Mounting interface
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H /
NFPA D03
DIN 24340 A10 / ISO 4401 / CETOP RP 121-H
/ NFPA D05
Mounting position unrestricted, preferably horizontal
Ambient temperature °C -25...+50
Weight kg 1,5 (1 solenoid), 2,1 (2 solenoids) 4,8 (1 solenoid), 6,3 (2 solenoids)
Hydraulic
Max. operating pressure bar P, A B: 350; T: 210 (DC), T: 140 (AC) P, A B: 350; T: 210 (DC), 105 (AC)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature °C -25 ... +70
Viscosity permitted cSt 2,8...400
Viscosity recommended cSt 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. l/min 80 150 (DC); 115 (AC)
Leakage at 50 bar ml/min Up to 10 per ow path, depending on spool Up to 20 per ow path, depending on spool
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency 1/h 15000 10000
Protection class IP 65 in accordance with EN 60529 (plugged and mounted)
G012 G024 W110 W230 G012 G024 W110 W230
Supply voltage V 12 24 110/50Hz 230/50Hz 12 24 110/50Hz 230/50Hz
Tolerance supply voltage % ±10 ±10 ±5 ±5 ±10 ±10 ±5 ±5
Current consumption hold A 2,72 1,29 0,6 0,3 3 1,5 0,8 0,4
Current consumption in rush A 2,72 1,29 2,5 1,25 3 1,5 3,41 1,75
Power consumption hold W 32,7 31 70 70 36 36 88 88
Power consumption in rush W 32,7 31 280 280 36 36 375 385
Wiring min. mm² 3 x 1,5
Wiring length max. m 50
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Hydraulic Valves
6
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Ordering Code HE**D
HE 10
Nominal size
06 NG6 (Cetop 03)
10 NG10 (Cetop 05)
D 3A
Spool types
3 position spools
06D 10D
3 position spools
06D 10D
2 position spools
06D 10D
3A 3N 2A
3B 3O 2B
3C 3P 2C
3D 3Q 2D
3E 3R 2E
3F 3S 2F
3G 3T
3H 3U
3I 3V
3J 3W
3K 3X
3L 3Y
3M 3Z
Control
D direct control (NG6 - NG10)
Operation
HE
electric operating
Directional Control Valve
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
7
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Ordering Code HE**D
00
Spool positions
Symbol
Spool
type
Spring
offset
Operated
00 3 „0“ „a“ od. „b“
01 3 „0“ „a“
Spool type 3H, 3I, 3Y, 3Z;
Operated -> „b“
02 3 „b“ „0“
Spool type 3H, 3I, 3Y, 3Z;
Spring offset -> „a“
03 3 „0“ „b“
Spool type 3H, 3I, 3Y, 3Z;
Operated -> „a“
04 3 „a“ „0“
Spool type 3H, 3I, 3Y, 3Z;
Spring offset -> „b“
05 3
-
„0“ od. „b“
Spool type 3I,
Operated -> „a“ od. „0“
06 3
-
„0“ od. „a“
Spool type 3I,
Operated -> „b“ od. „0“
07 2 „b“ „a“
08 2
-
„a“ od. „b“
09 2 „a“ „b“
N H
Solenoid
A Junior Timer - 2-PIN AMP
D Connector “Deutsch“ DP4 2-pin
H Solenoid connector as per EN 175301-803
Option
w/o Standard Valve without Option
09 End position monitored side B
10 Start position monitored side B
11 End position monitored side A
12 Start position monitored side A
Seals
N NBR
V VITON
G024
Voltage
G012 12V
G024 24V
W110 110V / 50Hz
W230 230V / 50Hz
1
Solenoid option
Design
06D 10D
1 Standard solenoid
2 without manual override
3 Soft shift „soft“
4 Soft shift „medium“
5 High pressure solenoid tube for AC
Hydraulic Valves
8
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Flow Curve Diagram HE06D


6ISKOSITÊTC3TBEI#
6OLUMENSTROM;LMIN=
$R
UCKABFALL;BAR=



  




Spool
Position “b” Position “a” Position “0”
P - A B - T P - B P - B A - T P - A P - A P - B A - T B - T P - T
3A 2 2 - 2 2 - - - - - -
3B 1 4 - 1 4 - - - - - -
3C 3 4 - 3 6 - 1 1 5 5 2
3D 2 3 - 2 3 - - - 7 - -
3E 2 2 - 2 2 - - - 7 7 -
3F 1 4 - 1 4 - 12 - - - -
3G 3 2 - 2 2 - 7 7 - - -
3J 3 - - 3 - - - 3 - 2 7
3K 2 2 - 2 2 - - - - - -
3L 3 2 - 2 2 - - - 14 14 -
3M 3 6 - 3 4 - 3 - 2 - -
3N 2 2 - 2 2 - - - - - -
2A 4 4 - 2 3 - - 12 - - -
2B 4 - - 4 - - - - - - -
2C 2 3 - 1 2 - - - - - -
3S 4 - 8 3 3 - - - 5 7 -
3T 3 3 - 4 - 8 - - 7 5 -
3V 13 13 - 13 13 - - - - - -
3W 13 13 - 13 13 - - - - - -
2E 11 10 - 10 9 - - - - - -
3X 1 4 - 1 4 - 5 5 8 8 6
3U 1 3 - 1 3 - 3 2 - - -
2D09 5 2 - 5 2 - - - - - -
2F 3 - - 2 - - - - - - -
P - B A - T P - A B - T
3H 4 5 - 4 5 - - - - - 9
3I 5 5 - 6 7 - - - - - 7
2D07 5 2 - 5 2 - - - - - -
3Y 1 3 - 4 3 - 7 - 4 - 7
3Z 4 3 - 1 3 - - 7 - 4 5
Spool
Position “b” Position “a”
P - A P - B A - B P - B A - T A - B
3O 2 4 - 4 2 -
B - T P - A P - B
3P 6 2 - 5 2 -
Pressure drop [bar]
Viscosity 40 cSt at 50°C.
Flow [l/min]
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
9
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Flow Curve Diagram HE10D
Spool
Position “b” Position “a” Position “0”
P - A B - T P - B A - T P - A P - B A - T B - T P - T A - B
3A 4 3 4 3 - - - - - -
3B 4 1 4 1 3 3 1 1 5 1
3C 4 3 5 2 - - 4 - - -
3D 4 2 4 2 - - 3 3 - 5
3E 4 3 5 3 5 - - - - -
3F 4 3 4 3 6 6 - - - 6
3G 5 1 4 3 - 4 - 2 6 -
3J 4 - 4 - - - - - - -
3K 4 3 4 3 - - 8 8 - -
3L 4 3 5 1 4 - 2 - 6 -
3M 5 2 4 3 - - - 4 - -
3N 5 3 4 3 - 5 - - - -
2A 4 3 4 3 - - - - - -
2B 4 - 4 - - - - - - -
2C 4 2 4 2 - - - - - -
P - B A - T P - A B - T P - A P - B A - T B - T P - T A - B
3H 4 3 4 3 - - - - 6 -
3I 4 4 4 4 - - - - 6 -
Position “b” Position “a”
P - A P - B A - B P - B A - T
3O 5 4 6 3 3
3P P - A B - T P - A P - B A - B
3 3 - 4 5 6
$URCHmUSSKENNLINIE
Pressure drop [bar]
Flow [l/min]
Hydraulic Valves
10
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Shift Limits HE**D
The diagram below species the shift limits for valves with DC solenoids. Valves with spool position “02” or “04” can
only be operated up to 70% of the limits.The shift limits can be considerably lower at unbalanced ow conditions.
To avoid ow rates beyond the shift limits, a plug-in orice can be inserted in the P-port.
Schaltleistungsgrenzen mit DC-Magnet
Schaltleistungsgrenzen AC-Magnet
Gemessen mit HLP46 bei 50°C, 95% U
nom
und betriebswarmen Magneten.
'EMESSENBEI5
NOM
UNDBETRIEBSWARMEN-AGNETEN
3CHALTLEISTUNGSGRENZEN'LEICHSPANNUNG
3CHALTLEISTUNGSGRENZEN7ECHSELSPANNUNG
Valve with standard DC solenoid (HE06D)
Valve with standard DC solenoid (HE10D)
3V
3W
3K
2A, 2C
3O, 3P
3C, 3D, 3M
3G, 3H,
3I, 3L,
2D
3E, 3N
3J
2B
3A, 3B, 3F
3I, 2C07/09
3H
3G, 3L
2A08, 2B08, 2C08
3H, 3I, 2C07/09
3G, 3L
3K
3J, 3O, 3P,
2B07/09
3A, 3B, 3C, 3D, 3E, 3M, 3N,
2A07/09
Pressure [bar]
Flow [l/min]
Pressure [bar]
Pressure [bar]
Flow [l/min]
Flow [l/min]
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
11
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Shift Limits HE**D
Schaltleistungsgrenzen mit DC-Magnet
Schaltleistungsgrenzen AC-Magnet
Gemessen mit HLP46 bei 50°C, 95% U
nom
und betriebswarmen Magneten.
'EMESSENBEI5
NOM
UNDBETRIEBSWARMEN-AGNETEN
3CHALTLEISTUNGSGRENZEN'LEICHSPANNUNG
3CHALTLEISTUNGSGRENZEN7ECHSELSPANNUNG
Valve with standard AC solenoid (HE06D)
Valve with standard AC solenoid (HE10D)
3A
3F, 2C
3D
3B
2B
3E, 3H,
3N, 2A
3G,
3L, 3V
2E
3W
3I,
3K,
3X
3C, 3M,
3Y, 3Z
3J,
3O, 3P
2A08, 2C08
3B
3K
3I
3G, 3H, 3L
3A, 3F, 2A07/09
3C, 3D, 3E, 3M, 3N, 2C07/09
3F
3A, 3C, 3D, 3E, 3M, 3N,
2A07/09, 2C07/09
Pressure [bar]
Flow [l/min]
Pressure [bar]
Flow [l/min]
Pressure [bar]
Flow [l/min]
Hydraulic Valves
12
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Shift Limits HE**D
Schaltleistungsgrenzen Soft Shift mit 1 DC-Magnet
Schaltleistungsgrenzen Soft Shift mit 2 DC-Magneten
Gemessen mit HLP46 bei 50°C, 90% U
nom
und betriebswarmen Magneten.
'EMESSENBEI5 UNDBETRIEBSWARMEN-AGNETEN
Shift limit diagram - Soft shift with 1 DC-solenoid (HE06D)
Schaltleistungsgrenzen Soft Shift mit 1 DC-Magnet
Schaltleistungsgrenzen Soft Shift mit 2 DC-Magneten
Gemessen mit HLP46 bei 50°C, 90% U
nom
und betriebswarmen Magneten.
Shift limit diagram - Soft shift with 2 DC-solenoids (HE06D)
Shift limit diagram - Soft shift (HE10D)
2E
3X
3B
2A
2E
2C
3A, 3D,
3V
2A08
3B
3I
3V,
3W
3A,
3D
3H, 3I
3G, 3H,
3I, 3J, 3L
3O, 3P,
2B, 3W
3C, 3D,
3KI, 3M,
2C
3A, 3B, 3E, 3F,
3N, 2A, 3V
2A08, 2B08, 2C08
Pressure [bar]
Flow [l/min]
Pressure [bar]
Flow [l/min]
Pressure [bar]
Flow [l/min]
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
13
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Response times HE**D
Valve Solenoid Energize De-energize
HE06D
Standard DC
45-60 20-30
Standard AC 13 20
Standard DC
rectier
60-70 70-90
HE10D
Standard DC 105 85
Standard AC 21 35
Valve
Sole-
noid
Orice
size
2 Magnet Ventil
MittelPosition: geschlossen
2 Magnet Ventil
MittelPosition: offen
1 Magnet Ventil
Energize De-energize Energize De-energize Energize De-energize
HE06D
3 0,5 mm
200-750 310-650 220-400 350-750 90-350 160-500
4 0,75 mm 180-300 300-400 200-350 300-500 90-350 130-350
Response times standard solenoid (Code 1)
Response times Soft Shift
Valve
Sole-
noid
Orice
size
Energize De-energize
HE10D
3 1,0 mm
320 550
4 1,75 mm 160 370
Step response times were obtained under the following conditions: υ = 40 mm2/s at 50°C with the valve operating at nominal pressure and ow.
Published response times are nominal and may vary with spool, ow, pressure and temperature.
Step response times were obtained under the following conditions:
υ = 35 mm2/s at 50°C with the valve operating at 175 bar and 65 l/min.
Published response times are nominal and may vary with spool, ow, pressure and temperature.
A B
HE06D
HE10D
Orice in anchor
Hydraulic Valves
14
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Dimensions HE06D
Ausführungen C, D / 03, 09
Ausführungen C, D / 03, 09
Ausführungen H, K, M / 02, 05
Anschluss nach EN 175301-803, DC-Magnet
Ausführungen B, E, F / 01, 06
Option J8, arretierbare Kugelnothand
(nur Ausführung 01, 06 dargestellt)
Ausführungen H, K, M / 02, 05
Anschluss nach EN 175301-803, AC-Magnet
Ausführungen B, E, F / 01, 06
Interface EN 175301-803, DC solenoid
Design 01, 02, 07
Design 03, 04, 09
Design 00, 08
Interface EN 175301-803, AC solenoid
Design 01, 02, 07
Design 03, 04, 09
Design 00, 08
Surface nish
4 x M5x30
DIN 912 12.9
7,6 Nm
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
15
IH-TDB-001-B/EN wrc_2010-08-25
Directional Control Valves
1.1
Dimensions HE10D
!USFàHRUNGEN#$
!USFàHRUNGEN#$
!NSCHLUSSNACH%.!#-AGNET
!USFàHRUNGEN"%& !USFàHRUNGEN(+-
!NSCHLUSSNACH%.$#-AGNET
!USFàHRUNGEN"%& !USFàHRUNGEN(+-
Interface EN 175301-803, DC solenoid
Design 01, 02, 07
Design 03, 04, 09
Design 00, 08
Interface EN 175301-803, AC solenoid
Design 01, 02, 07
Design 03, 04, 09
Design 00, 08
Surface nish
4 x M6x40
DIN 912 12.9
13,2 Nm
±15%
Hydraulic Valves
16
IH-TDB-001-B/EN wrc_2010-08-25
Hydraulic Valves
IH-TDB-001-B/EN wrc_2010-08-25
Notes
1.1